Human Erythropoietin Quantikine ELISA Kit, RUO
Human Erythropoietin Quantikine ELISA Kit, RUO
Human Erythropoietin Quantikine ELISA Kit, RUO

Human Erythropoietin Quantikine ELISA Kit, RUO

 詳情說(shuō)明

深圳子科生物優(yōu)勢(shì)代理美國(guó)R&DELISA系列產(chǎn)品試劑盒,價(jià)格優(yōu)勢(shì),貨期短,歡迎來(lái)電咨詢0755-33164177!

Human Erythropoietin Quantikine ELISA Kit, RUO Summary

貨號(hào):DEPRU0  規(guī)格:96T

Assay Length
4.5 hours (Benchtop Protocol) or 2.5 hours (Shaker Protocol)
Sample Type & Volume Required Per Well
Serum (100 uL), EDTA Plasma (100 uL)
Sensitivity
0.6 mIU/mL
Assay Range
2.5 - 200 mIU/mL (Serum, EDTA Plasma)
Specificity
Natural and recombinant human Epo.
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
Interference observed with other substances.

Product Summary

The Quantikine® Human Epo ELISA uses a monoclonal antibody and polyclonal antibody conjugate in a sandwich ELISA format. The assay is designed to measure Epo levels in serum or EDTA plasma in less than 4.5 hours, or less than 2.5 hours using the shaker protocol.

Precision

Benchtop Protocol Precision (Precision within an assay) Four samples of known concentration were tested thirty times to assess intra-assay precision
Shaker Protocol Precision (Precision between assays) Four samples of known concentration were tested in thirty separate assays to assess inter-assay precision. Assays were performed by at least three technicians using three lots of components

Serum, EDTA Plasma

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 4 1 2 3 4
n 30 30 30 30 30 30 30 30
Mean 5.82 16.01 25.18 79.02 6.45 16.22 26.35 84.14
Standard Deviation 0 0 0 0 0 0 0 0
CV% 8.25 4.3 5.9 4.24 10.3 3.74 4.2 3.71

Recovery

The recovery of human Epo spiked to levels throughout the range of the assay was evaluated.

Sample Type Average % Recovery Range %
Serum (n=)

Linearity

Five matched serum and plasma specimens containing elevated Epo concentrations were diluted with Specimen Diluent and assayed using the Quantikine Human Epo ELISA. Diluted specimens demonstrated very good linearity when compared to neat concentrations of Epo.
Human Epo ELISA Benchtop Protocol Linearity
Human Epo ELISA Shaker Protocol Linearity